What we provide

Holistic solutions and services of high standards

a few words
Our experience, reliability and professional responsibility put us in a leader position in subject of the wastewater management.  Since 2006, company is specialized in providing technical consultancy on design, construction, management and maintenance of wastewater treatment plants.

With over 15 years experience in wastewater management we stay close with our customers and learning from their problems. Our strategic partnerships with companies that are global leaders in waste water industry, we are the most suitable people to provide technical and consultant support in,

  • Supply and installation the equipment (pumps, mixers)
  • Aerators, blowers
  • Sludge management
  • Control and Monitoring equipment (Scada, level sensors, flow meters, DO meters, etc.)
  • Support and Service all the electromechanical equipment of the wwtp.
  • Consultant and Management on the operation of the waste water treatment plant.
  • Compact WasteWater Treatment Plants

ANNUAL MAINTENANCE SUPPORT SERVICES

ANNUAL MAINTENANCE OF FIREFIGHTING SYSTEMS

ANNUAL PUMPS MAINTENANCE

ANNUAL MAINTENANCE OF EQUIPMENT AND OPERATION OF BIOLOGICAL STATIONS

activity sections

Pumps
Agitation
Playgrounds
Circulators
Ventilation
Blowers
Thick, thin bubble diffusers
Measuring instruments (weights, floats, flowmeters)
SCADA
Pump control units (PLCs, Microcontrollers)

WHAT IS BOD & COD

The organic components of the waste consist mainly of proteins, hydrocarbons, lipids and surfactants in proportions,

40-60% proteins, 25-50% hydrocarbons, 10% lipids

However, the measurement of organic ingredients becomes practically impossible due to their complexity. The term “BOD” or “COD” denotes the polluting load of the organic ingredients.

More specifically,

Biochemical Oxygen Demand (BOD)
It expresses the amount of oxygen needed by the microorganisms found in the active sludge to oxidize the organic constituents of the nitrite and nitrate waste under aerobic conditions.
Chemical Oxygen Demand (COD)
It is the amount of oxygen needed to completely oxidize the organic components of the waste to carbon dioxide and water in acidic conditions.

TYPICAL SPECIFICATIONS

Biochemically Required Oxygen (BOD5)                 ≤ 25 mg / l

Chemical Required Oxygen (COD)                            ≤ 125 mg / l

Total Solids Suspension (TSS)                                     ≤ 35 mg / l

Total Kjeldahl Nitrogen (TKN)                                    ≤ 35 mg / l

Ammoniacal nitrogen (NH3)                                        ≤ 2 mg / l

Total Phosphorus (TP)                                                   ≤ 2 mg / l

Contact Us